Adept Scientific - Danmark
Verdens førende software inden for Industri, Forskning & Udvikling.
flag arrow
clearclear
Flag

 Adept Store | register Join My Adept | Flags  
Adept Scientific A/S | Produktionsvej 26 | DK-2600 | Glostrup | Danmark | Tel: +45 48 25 17 77  
UKdedksvnofi
spacer
spacerHjemspacer
spacer
spacerProdukterspacer
spacer
spacerKurserspacer
spacer
spacerServicesspacer
spacer
spacerspacer E-Shopspacer
spacer
spacerDownloadsspacer
spacer
spacerUddannelsespacer
spacer
spacerSupportspacer
spacer
spacerMit Adeptspacer
spacer
spacerspacerspacer
International |  Om os |  Blog |  Kontakt os |  Presse |  Job & Karriere
Adept Scientific on Facebook Adept Scientific on Twitter Adept Scientific on YouBube Adept Scientific on LinkedIn
Adept Scientific Knowledge Base
Knowledge Base Home  > Browse Categories  > WinWedge
WinWedge
 

 Results 1 - 10 - 29. Next»»

Date Modified 

Can you send a command from WinWedge to the instrument to switch baud rate & then start receiving data in the new baud rate?
null I have an instrument that can transmit at two different baud rates 9600 & 56000. Can you send a command from WinWedge to the instrument to switch baud rate & then start receiving data in the new baud rate? Yes you can send commands from the wedge to your instrument. Changing the baud rate can ....
Category: Laboratory Applications > WinWedge 4th Aug 2009

Can you run both version the Std & Pro versions of WinWedge on the same PC?
null You can install both versions of the Wedge on the same PC however if you try to run both at the same time, what will happen is that Windows will run two instances of the same version that you run first. This is because they both have the same executable file name and Windows always checks befo....
Category: Laboratory Applications > WinWedge 4th Aug 2009

Can WinWedge handle output from a RS485 serial device?
null Typically you would need to convert from RS485 to RS232 before you would be able to plug the device into a serial port on your PC. RS485 to RS232 converters can be purchased for under ?70. (There are two types of RS485 to RS232 converters - ones that turn the RTS line around automatically and ....
Category: Laboratory Applications > WinWedge 4th Aug 2009

Will WinWedge work with instruments that use the modbus protocol rather than ASCII?
null WinWedge does not support the Modbus protocol. Modbus is a high level protocol that defines the communications process between (usually) industrial controllers. Modbus uses ASCII data however it also uses check digits, timeouts and special framing characters that make the protocol a little mor....
Category: Laboratory Applications > WinWedge 4th Aug 2009

WinWedge & Modems
null WinWedge can be used to send and receive data over a modem. It can also be used to automate electronic dialling and transmitting signal tones as it supports full 2-way communications. Hence it is perfect for collecting and transmitting data over modems from Access, Excel and other Windows appl....
Category: Laboratory Applications > WinWedge 4th Aug 2009

Can WinWedge be used with an instrument which uses checksums
null I need to collect some data, calculate a checksum on the data, then send the data & the result of the checksum to the instrument to see if the instrument gets the same result. Could WinWedge be used in this example? The Wedge by itself does not have the ability to calculate checksums however i....
Category: Laboratory Applications > WinWedge 4th Aug 2009

Do I need to use a duplex or a simplex adapter to connect a Bowyers or a Sylvac dial counter to the PC?
null The Bowers/Sylvac devices support 2 way I/O even with the simplex cable. In other words, you can set up the Wedge to prompt the indicator at a specific time interval no matter if you use a simplex or a duplex adapter. null null WinWedge null - en null null....
Category: Laboratory Applications > WinWedge 4th Aug 2009

Modems
null Can WinWedge be used for getting data from a remote site via a modem? Would I need to use TCP/IP wedge for this? Does it make a difference if it is an internal modem? Could you use WinWedge to activate the modem through dial up networking? You could use WinWedge to control a modem, either by a....
Category: Laboratory Applications > WinWedge 4th Aug 2009

MUX 2 & 4 Protocol
null MUX 2 & 4 Protocol Format of data after pressing data button on gauge or sending command code. N_MT_SZZZZZZZZ_EEEEEECRLF _ : Is a blank N : Number of input channels(1-4) MT : Two characters representing type of data. (MW=Measured value) S : Sign (+ of -) of data ZZZZZZZZ : Measurement da....
Category: Laboratory Applications > WinWedge 4th Aug 2009

Can WinWedge cope with varying record lengths?
null Can WinWedge cope with varying record lengths? The instrument's record starts with an ID, followed by two bytes which tell you how long the record is, then the record, then a checksum & then an end of record character (the hex symbol for 77). Would WinWedge be able to parse this correctly? Yes....
Category: Laboratory Applications > WinWedge 4th Aug 2009



 Results 1 - 10 - 29. Next»»
 

Highly Rated Articles

1. Requesting data from an instrument

2. Setup.exe fails to install WinWedge 32 Pro on some older Windows 95/NT systems

3. Can you collect data from multiple instruments, connected to a COM port via a multiplexor, or do you need to have them connected to multiple COM ports?

4. Real-time charting

5. No data is appearing in the Port Analyse Window


adept

Tilbage til sidestart

Popular Links: ChemDraw | ChemOffice | Data Acquisition | Data Analysis | EndNote | Maple | MapleSim | Mathcad | MathType | Quality Analyst | Reference Manager | VisSim

EU ePrivacy Directive | Erklæring om privat ret og forretningsbetingelser
Alle varemærker anerkendes og respekteres. Fortrolighedserklæring © 2012, Adept Scientific.
Da nogle af vores sider er med engelsk tekst, bedes du kontakte vores lokale kontor såfremt du har spørgsmål
Dette site vedligeholdes af Lyndon Ash

Adept Scientific A/S | Produktionsvej 26 | DK-2600 | Glostrup | Danmark | Tel: +45 48 25 17 77