Adept Scientific - Danmark
Verdens førende software inden for Industri, Forskning & Udvikling.
flag arrow
clearclear
Flag

 Adept Store | register Join My Adept | Flags  
Adept Scientific A/S | Produktionsvej 26 | DK-2600 | Glostrup | Danmark | Tel: +45 48 25 17 77  
UKdedksvnofi
Hjem
Produkter
Kurser
Services
 E-Shop
Downloads
Uddannelse
Support
Mit Adept
International |  Om os |  Blog |  Kontakt os |  Presse |  Job & Karriere
Adept Scientific on Twitter Adept Scientific on LinkedIn


Gå videre

• Ask us a question
•  Download a Demo
•  Request a Brochure

Lær mere

Quanser Home
The Quanser Difference
Comparison Chart
Quanser Engineering Blog

Control Experiments
Linear
Rotary
Specialty
 - 2 DOF Helicopter
 - 3 DOF Helicopter
 - 3 DOF Hover
 - 3 DOF Crane
 - Direct Drive Rotary Servo
 - Planar Rotray IP
 - Solar Tracker
 - Coupled Tanks
 - 5 DOF CRS Robot
 - Heat Flow (HPE)
 - Shake Table l
 - Shake Table ll
 - Smart Structure
 - Magnetic Levitation
 - XY Shake Table lll
 - 2 DOF Flexible Serial Link
 - 2 DOF serial flexible joint
 - Cube
 - 5 DOF Haptic Wand
 - Omni Bundle

Mechatronics
Unmanned Vehicle Systems

QUARC 2.0

Service & Support

Search the Knowledge Base
Technical Support request

Quanser

Coupled Tanks

iml_S13-tanks.gif

Challenge:
Design a control system to regulate the water level in multiple coupled tank systems.

Description:
The "Two Tank Module" consists of a pump with a water basin. The pump thrusts water vertically to two quick connect, normally closed orifices "Out1" and "Out2". These two orifices have different diameters. Two tanks mounted on the front plate are configured such that flow from the first tank flows into the second tank and outflow from the second tank flows into the main water basin. The outflows from the two tanks are variable by changing inserts that screw into the tapped holes. Rubber tubing with appropriate couplings is supplied to enable the pump to feed water into one or both tanks. The selection of outputs from the pump controls the flow ratio between the two outputs. This single system can be configured into 3 types of experiments each with various parameters.
Configuration #1:
SISO system. The pump feeds into Tank 1 and you design a controller that regulates the level in Tank 1. Tank 2 is not used at all.
Configuration #2:
State coupled SISO system. The pump feeds into Tank 1, which in turn feeds into Tank 2. Design a controller that regulates the levels in Tank 2. Try different orifices in Tank 1 and Tank 2.
Configuration #3:
State coupled and input coupled SISO system. The pump feeds into Tank 1 and into Tank 2 using a split flow. Tank 1 also feeds into Tank 2. Design a controller that regulates the levels in Tank 2.

Difficulty:
Undergraduate / Graduate


Ready to buy?

Every customer requirement for the Quanser range is unique and we offer pre-sales support to ensure your purchase fully meets the project requirements.

For more information about Quanser Control Challenges and to discuss your project contact our Quanser team at your local office.

Latest Downloads

Quanser Case Study: University of Central Florida - Accelerating Research by Allowing Two Programming Languages to Talk
Quanser Case Study: University of Victoria Driving Haptic-Based Rehabilitation Further and Faster
Quanser Robotics Platform Brochure - COPY
Quanser Rotary Control Experiments - COPY
Quanser Case Study: McMaster University Increases Enrollment by Re-engineering Biomedical Education

Latest News

Quanser Case Study: University of Central Florida - Accelerating Research by Allowing Two Programming Languages to Talk
Quanser Case Study: University of Victoria Driving Haptic-Based Rehabilitation Further and Faster
Quanser Case Study: McMaster University Increases Enrollment by Re-engineering Biomedical Education
"The Quanser Shake Table...
Quanser Case Study - Shake Table teaching aid supports earthquake-affected building design
adept

Tilbage til sidestart

Popular Links: ChemDraw | ChemOffice | Data Acquisition | Data Analysis | EndNote | Maple | MapleSim | Mathcad | MathType | Quality Analyst | Reference Manager | VisSim

EU ePrivacy Directive | Erklæring om privat ret og forretningsbetingelser
Alle varemærker anerkendes og respekteres. Fortrolighedserklæring © 2012, Adept Scientific.
Da nogle af vores sider er med engelsk tekst, bedes du kontakte vores lokale kontor såfremt du har spørgsmål
Dette site vedligeholdes af Lyndon Ash

Adept Scientific A/S | Produktionsvej 26 | DK-2600 | Glostrup | Danmark | Tel: +45 48 25 17 77